VAT/Tax Code 01781440043
Business Register: CN-135960
Share Capital: 2,000,000 paid-up.
Sector: Energy / District Heating Networks
Client: Italy – Moretta (CN)
Year: 2022
Objective:
Design and construction of a thermal storage tank for hot water, integrated into a district heating network, with the goal of optimising and stabilising energy supply.
Technical Specifications:
- Nominal volume: 1,300 m³
- Internal diameter: Ø 8,400 mm
- Total height: ~ 21,500 mm
- Material: Steel S355J2
- Empty weight (with internals): 39,000 kg
- Design pressure: atmospheric (hydrostatic up to +2 barg)
- Design codes: EN 14015, API 650
- Accessories:
Key Strengths:
- Custom design for high-volume tanks and next-generation networks
- Perfect integration with existing foundations
- Robust and highly safe structure
- On-site construction with complex logistics management
- Contribution to regional energy transition initiatives
- 2022